Particle management for HVAC systems
Journal Article
·
· ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States)
OSTI ID:6012665
- Ohio Air Filter, Sylvania, OH (United States)
Filtration systems that are incorrectly selected, installed and maintained can cause excessive particulates in occupied spaces. This article describes how to identify and correct problems. Particulate matter can be removed from ventilation air at several sites within a building. These sites include: on heat exchanger surfaces; inside ductwork, ceiling tiles and diffusers; and in the air filter. The cost associated with removing these unwanted contaminants is unavoidable. However, this removal cost varies depending on where the particulates have been deposited. Not all particulates that are generated by work-related activities are transported to the filter bank by return air currents before being deposited on other surfaces. Accordingly, walls still have to be repainted at varying intervals and carpeting vacuumed. Ceiling tiles will discolor at a rate that is influenced by their texture, the air outlet velocity, the amount of dirt in the ventilation air and how much contaminant is being generated in the room. It is estimated that 15% of ventilation air escapes the air filtration process. This leakage results in higher utility, janitorial and redecorating costs as well as contributing to employee absenteeism. When building management does not prevent it, air-conditioning coils and ductwork become an unintended part of the building's air filtration system. In time, this is much more expensive both in energy and cleaning costs than the steps available to keep them clean. Good particulate control can lower the total cost of building operation. However, a building operator may not have to upgrade to a higher efficiency filter to achieve higher system efficiency. Simply eliminating the source of leaks and better management of the existing filters may be all that is necessary.
- OSTI ID:
- 6012665
- Journal Information:
- ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States), Journal Name: ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States) Vol. 35:7; ISSN 0001-2491; ISSN ASHRAA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Filtration efficiency of the plant sand filter
Plutonium finishing plant remediation project: Exhaust manifold
Evaluation of two cleaning methods for the removal of asbestos fibers from carpet
Technical Report
·
Thu Jun 15 00:00:00 EDT 1950
·
OSTI ID:6820266
Plutonium finishing plant remediation project: Exhaust manifold
Conference
·
Sun Jul 01 00:00:00 EDT 1990
·
OSTI ID:6893039
Evaluation of two cleaning methods for the removal of asbestos fibers from carpet
Technical Report
·
Sun Dec 31 23:00:00 EST 1989
·
OSTI ID:6066314
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
320107 -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR CLEANING
AIR FILTERS
AIR POLLUTION MONITORING
AIR QUALITY
CLEANING
ENERGY SYSTEMS
ENVIRONMENTAL QUALITY
EQUIPMENT
FILTERS
MONITORING
PARTICLES
PARTICULATES
PERFORMANCE
POLLUTION CONTROL EQUIPMENT
SPACE HVAC SYSTEMS
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
320107 -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR CLEANING
AIR FILTERS
AIR POLLUTION MONITORING
AIR QUALITY
CLEANING
ENERGY SYSTEMS
ENVIRONMENTAL QUALITY
EQUIPMENT
FILTERS
MONITORING
PARTICLES
PARTICULATES
PERFORMANCE
POLLUTION CONTROL EQUIPMENT
SPACE HVAC SYSTEMS