Degradation characteristics of Au-Si nuclear detectors by a few Mev charged particle irradiation

Journal Article · · IEEE Trans. Nucl. Sci.; (United States)
It is found that a Si surface barrier detector has been degraded after 3.2 MeV protons or 3.5 MeV /sup 3/He particle irradiation with low doses ranging from 10/sup 11/ to 10/sup 12/ cm/sup -2/. The degradation characteristics have been investigated through the changes in the reverse current, capacitance, alpha-particle counting response and DLTS measurements. /sup 3/He particle irradiation produces a change of the capacitance at lower reverse bias compared to that of proton irradiation, indicating the defect creation at the short penetration depth of /sup 3/He particles. Capacitance-voltage characteristics of the irradiated detectors can be simply analysed using Poisson's equation with an assumption that the charge defects are created within the depletion layers. Such kinds of defects are considered as electron traps at 0.36, 0.45 and 0.51 eV from the conduction band.
Research Organization:
Department of Electronics, Tohoku Institute of Technology, Yagiyama, Sendai 982
OSTI ID:
5953047
Journal Information:
IEEE Trans. Nucl. Sci.; (United States), Journal Name: IEEE Trans. Nucl. Sci.; (United States) Vol. 30:1; ISSN IETNA
Country of Publication:
United States
Language:
English