Field-performance audit procedures were developed for three of the most common total reduced sulfur (TRS) continuous-emission-monitoring systems (CEMS). These procedures were designed to assist state/federal field inspectors in the evaluation of TRS-CEMS. Contained in the notebook are checklists and data-entry tables covering preparation for the inspection, preliminary review of records, preliminary on-site meeting with source personnel, and general guidelines for inspection of any type TRS-CEMS. Specific audit procedures for three of the most common models of TRS CEMS: Sampling Technology Inc. Model 100 TRS CEM System; Barton Titrator TRS System; and Bendix Gas Chromatograph TRS System are provided as sectional inserts. In auditing these monitors the inspector should follow the specific procedure rather than the general guidelines given in the body of the field notebook. Conscientious use of this notebook will aid the inspector in conducting a thorough audit of the TRS CEMS and provide a comprehensive original record of all phases of the inspection.