Materials from selected EPICOR-II prefilter liners were collected and examined as part of the EPICOR and Waste Research and Disposition Program sponsored by the Department of Energy at the Idaho National Engineering Laboratory (INEL). The intent of that examination was to define the internal condition of liners and ensure that liners could be stored at INEL for ten years. This paper discusses the liner-integrity examination and presents the results of these examinations. Metallurgical examination of sections removed from the liners revealed no evidence of pitting or pitting-type corrosion. Measurements of wall thickness indicate that material was missing from the wall of PF-3 in an area where the protective coating had been removed to form a conductivity patch. If it is assumed that all thinning of the wall in that area is caused by corrosion, the liners will have a lifetime of approximately 50 years. 12 figures.
Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
5910653
Report Number(s):
EGG-02184; CONF-850314-26; ON: DE85008651
Country of Publication:
United States
Language:
English