Determination of the model parameters of machines from the reactance operators x[sub d](p), x[sub q](p) (Evaluation of standstill frequency response test)

Journal Article · · IEEE Transactions on Energy Conversion (Institute of Electrical and Electronics Engineers); (United States)
DOI:https://doi.org/10.1109/60.222718· OSTI ID:5900993
 [1]
  1. ABB Power Generation Ltd., Baden (Switzerland)

A method is presented for determining the characteristic quantities and model parameters from the given frequency responses x[sub d](js), x[sub q](js). The curves of values measured on a large turbogenerator at standstill are used as an example. The characteristic values and model parameters are determined for various models (with 4, 3 and 2 rotor circuits in each axis) and are compared with the results of the short-circuit tests and with advance calculations.

OSTI ID:
5900993
Journal Information:
IEEE Transactions on Energy Conversion (Institute of Electrical and Electronics Engineers); (United States), Journal Name: IEEE Transactions on Energy Conversion (Institute of Electrical and Electronics Engineers); (United States) Vol. 8:2; ISSN 0885-8969; ISSN ITCNE4
Country of Publication:
United States
Language:
English