Title: Variation in gated blood-pool image quality using in vivo, modified in vivo, and in vitro red blood cell labeling techniques

Journal Article · · J. Nucl. Med. Technol.; (United States)
OSTI ID:5875752

The scintigraphic results of three methods of labeling red blood cells (RBCs) were compared. Image quality was evaluated in 200 patient studies by measuring the left ventricle to background ratio. These studies were performed using either the in vivo, modified in vivo or in vitro method for labeling RBCs. The average ventricle to background ratio for the in vitro method was 2.85 compared to 2.42 and 2.20 for the modified in vivo and in vivo methods, respectively. The in vitro method gave a statistically higher ratio than did either the in vivo or the modified in vivo methods.

Research Organization:
Univ. of Utah Health Sciences Center, Salt Lake City
OSTI ID:
5875752
Journal Information:
J. Nucl. Med. Technol.; (United States), Vol. 14:2
Country of Publication:
United States
Language:
English

Similar Records

Cardiac chamber imaging: a comparison of red blood cells labeled with Tc-99m in vitro and in vivo
Journal Article · Wed Feb 01 00:00:00 EST 1978 · J. Nucl. Med.; (United States) · OSTI ID:5875752

Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin
Journal Article · Sat Jul 01 00:00:00 EDT 1978 · J. Nucl. Med.; (United States) · OSTI ID:5875752

Comparison of in vitro RBC labeling with the UltraTag RBC kit versus in vivo labeling
Journal Article · Fri Feb 01 00:00:00 EST 1991 · Journal of Nuclear Medicine; (USA) · OSTI ID:5875752