Latest developments and application of DB Riley`s low NOx CCV{reg_sign} burner technology
Conference
·
OSTI ID:585349
- DB Riley, Inc., Worcester, MA (United States)
Recent developments in DB Riley (DBR) low NO{sub x} burner technology and the application of this technology in coal fired utility boilers are discussed. Since the promulgation of the Clean Air Act Amendment in 1990, DBR has sold nearly 1500 Controlled Combustion Venturi (CCV{reg_sign}) burners on pulverized coal fired utility boilers reducing NOx emissions 50 - 70% from uncontrolled levels. This technology has been retrofitted on boiler designs ranging in size and type from 50 MW front wall fired boilers to 1300 MW opposed fired cell type boilers. In DBR`s latest version of the CCV{reg_sign} burner, a second controlled flow air zone was added to enhance NO{sub x} control capability. Other developments included improved burner air flow measurement accuracy and several mechanical design upgrades such as new coal spreader designs for 3 year wear life. Test results of the CCV{reg_sign} dual air zone burner in DBR`s 100 million Btu/hr (29 MW) coal burner test facility are presented. In the test program, coals from four utility boiler sites were fired to provide a range of coal properties. A baseline high volatile bituminous coal was also fired to provide a comparison with 1992 test data for the CCV{reg_sign} single register burner. The test results showed that the second air zone enhanced NO{sub x} reduction capability by an additional 20% over the single register design. Computational fluid dynamic (CFD) modeling results of the CCV{reg_sign} dual air zone burner are also presented showing near field mixing patterns conducive to low NO{sub x} firing.
- Research Organization:
- Coal and Slurry Technology Association, Washington, DC (United States)
- OSTI ID:
- 585349
- Report Number(s):
- CONF-980309--PROC.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Latest developments and application of DB Riley's low NOx CCV{reg{underscore}sign} burner technology
Latest results on reducing NOx emissions at American Electric Power's coal fired utility boilers with DB Riley's CCV burner technologies
DB Riley successfully retrofits 4500 MW of utility coal fired generating capacity with low NOx CCV{reg{underscore}sign} burner technology in 1998
Conference
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:20012961
Latest results on reducing NOx emissions at American Electric Power's coal fired utility boilers with DB Riley's CCV burner technologies
Conference
·
Sat Jul 01 00:00:00 EDT 2000
·
OSTI ID:20034358
DB Riley successfully retrofits 4500 MW of utility coal fired generating capacity with low NOx CCV{reg{underscore}sign} burner technology in 1998
Conference
·
Thu Jul 01 00:00:00 EDT 1999
·
OSTI ID:20006862