Latest results on reducing NOx emissions at American Electric Power's coal fired utility boilers with DB Riley's CCV burner technologies

Conference ·
OSTI ID:20034358
American Electric Power Service Corporation (AEP) and DB Riley, Inc., under an alliance arrangement, have retrofitted eight coal fired utility boilers with DB Riley's Controlled Combustion Venturi (CCV{reg_sign}) burners for reducing NOx emissions prior to SCR and/or SNCR installations on some of these units. These units all burn eastern bituminous coal and range in size from 260 to 1,300 MWn. The larger utility boilers are equipped with cell fired burners while the smaller units utilize more traditional single circular coal burners. The low NOx CCV{reg_sign} burner technology installed consisted of a variety of different designs including CCV{reg_sign} single register and CCV{reg_sign} cell burners. All burners were designed to be a ``plug into the existing waterwall openings'' type to preclude pressure part modifications. The most unique retrofit involved the installation of low NOx burners on all four-furnace walls of a 450 MWn utility boiler. Pre-retrofit baseline NOx levels on these eight (8) utility boilers ranged from 0.9 to 1.6 lb/mmbtu while post-retrofit NOx emission levels ranged from 0.42 to 0.70 lb/mmbtu. This represents about 50--60% reduction in NOx from uncontrolled levels using the burners only technology. This paper describes the latest results from this major low NOx burner retrofit project.
Research Organization:
DB Riley, Inc., Worcester, MA (US)
OSTI ID:
20034358
Country of Publication:
United States
Language:
English