Risk assessment of severe accident-induced steam generator tube rupture

Technical Report ·
DOI:https://doi.org/10.2172/582237· OSTI ID:582237

This report describes the basis, results, and related risk implications of an analysis performed by an ad hoc working group of the U.S. Nuclear Regulatory Commission (NRC) to assess the containment bypass potential attributable to steam generator tube rupture (SGTR) induced by severe accident conditions. The SGTR Severe Accident Working Group, comprised of staff members from the NRC`s Offices of Nuclear Reactor Regulation (NRR) and Nuclear Regulatory Research (RES), undertook the analysis beginning in December 1995 to support a proposed steam generator integrity rule. The work drew upon previous risk and thermal-hydraulic analyses of core damage sequences, with a focus on the Surry plant as a representative example. This analysis yielded new results, however, derived by predicting thermal-hydraulic conditions of selected severe accident scenarios using the SCDAP/RELAP5 computer code, flawed tube failure modeling, and tube failure probability estimates. These results, in terms of containment bypass probability, form the basis for the findings presented in this report. The representative calculation using Surry plant data indicates that some existing plants could be vulnerable to containment bypass resulting from tube failure during severe accidents. To specifically identify the population of plants that may pose a significant bypass risk would require more definitive analysis considering uncertainties in some assumptions and plant- and design-specific variables. 46 refs., 62 figs., 37 tabs.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Reactor Regulation
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
OSTI ID:
582237
Report Number(s):
NUREG--1570; ON: TI98004308
Country of Publication:
United States
Language:
English

Similar Records

Use of SCDAP/RELAP5 results in severe accident-induced tube rupture risk assessment
Journal Article · Sun Nov 30 23:00:00 EST 1997 · Transactions of the American Nuclear Society · OSTI ID:552620

Frequency and consequences associated with an SGTR (steam generator tube rupture) event
Conference · Sat Dec 31 23:00:00 EST 1988 · Transactions of the American Nuclear Society; (USA) · OSTI ID:6528139

SCDAP/RELAP5 Evaluation of the Potential for Steam Generator Tube Ruptures as a Result of Severe Accidents in Operating PWRs
Technical Report · Tue Sep 01 00:00:00 EDT 1998 · OSTI ID:911021