Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Soudan 2 data acquisition and trigger electronics

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:5810593

The 1.1 kton Soudan 2 calorimetric drift-chamber detector is read out by 16K anode wires and 32K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 200 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 80C86 microprocessor, which supervises a pipe-lined data compactor, and allows transfer of the compacted data via CAMAC to the host computer. The 80C86's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology.

Research Organization:
Argonne National Lab., Argonne, IL 60439
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
5810593
Report Number(s):
CONF-851009-
Journal Information:
IEEE Trans. Nucl. Sci.; (United States), Journal Name: IEEE Trans. Nucl. Sci.; (United States) Vol. NS-33:1; ISSN IETNA
Country of Publication:
United States
Language:
English