Tubing wastage in fluidized-bed coal combustors: Examinations of tubing from Test Series 2, NCB (IEA Grimethorpe) Ltd. Facility

Conference ·
OSTI ID:5784854
This study of wasted heat-exchanger tubing from the Grimethorpe PFBC Facility was conducted to characterize affected fireside surfaces and identify the mechanism/s responsible. Examinations showed that the wasted surfaces are not typical of those produced by erosion alone, as oxide deposits are present on all surfaces. Continual exfoliation of the normally-protective oxide layer is probably responsible for a major portion of tubing wastage. There are also indications of direct metal loss occurring through a series of events wherein repeatd formation and exfoliation of surface oxides produce an irregular metal interface that is mechanically deformed during combustor operation. The cold-worked metal protrusions, or platelets, on the roughened surface readily fracture from the tubing wall and are lost into the bed. 27 refs., 23 figs., 3 tabs.
Research Organization:
Lawrence Livermore National Lab., CA (USA)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5784854
Report Number(s):
UCRL-97569; CONF-871191-1; ON: DE88002668
Country of Publication:
United States
Language:
English