Radial tolerance stackup: ISIP

Technical Report ·
OSTI ID:5762990
A radial stackup analysis for the Intermediate Sodium Inducer Pump (ISIP) has been performed to determine the minimum-maximum clearances between the rotating and stationary components at room temperature. The effect of transient temperatures to these clearances will be determined as a part of the thermal transient analysis. The calculated radial clearances at the inducer blade tip for the four conditions examined are: 0.050 to 0.055 in. for all fits and bearing clearance being concentric; 0.069 to 0.036 in. for maximum parallel offset of all fits and clearances of static/hydraulic diffuser assembly and impeller assembly; 0.077 to 0.028 in. for maximum parallel offset of all fits and clearances, and maximum angularity of stationary components; and 0.0930 to 0.0120 in. for worst condition of parallel offsets and angularity.