A technique using a soft-flow molding epoxy and a transfer press to fill EMR hardware was found to reduce manufacturing time and scrap yield for shielded multiwire cables. Samples representative of production cables were subjected to mechanical and temperature shock, humidity, and vibration. The results indicated that this epoxy could prevent or reduce EMR hardware collapse from molding pressures during fabrication, thereby reducing scrap and increasing cable production yield.