Preliminary risk assessments of the small HTGR
Conference
·
OSTI ID:5730366
Preliminary investment and safety risk assessments were performed for a preconceptual design of a four-module 250-MW(t) side-by-side steel-vessel pebble bed HTGR plant. Broad event spectra were analyzed involving component damage resulting in unscheduled plant outages and fission product releases resulting in offsite doses. The preliminary assessment indicates at this stage of the design that two categories of events govern the investment risk envelope: primary coolant leaks which release some circulating and plate-out activity that contaminates the confinement and turbogenerator damage which involves extensive turbine blade failure. Primary coolant leaks are important contributors because associated cleanup and decontamination requirements result in longer outages that arise from other events with comparable frequencies. Turbogenerator damage is the salient low-frequency investment risk accident due to the relatively long outages being experienced in the industry. Thermal transients are unimportant investment risk contributors because pressurized core heatups cause little damage, and depressurized core heatups occur at negligible frequencies relative to the forced outage goal. These preliminary results demonstrate investment and safety risk goal compliance at this stage in the design process. Studies are continuing in order to provide valuable insights into risk-significant events to assure a balanced approach to meeting user and regulatory requirements.
- Research Organization:
- GA Technologies, Inc., San Diego, CA (USA)
- DOE Contract Number:
- AT03-84SF11963
- OSTI ID:
- 5730366
- Report Number(s):
- DOE/HTGR-85-027; CONF-850570-2; ON: DE85011736
- Country of Publication:
- United States
- Language:
- English
Similar Records
Investment risk assessment of the HTGR steam cycle/cogeneration plant
Forced outage assessment for the MHTGR [Modular High-Temperature Gas-Cooled Reactor]
Analysis of risk reduction methods for interfacing system LOCAs (loss-of-coolant accidents) at PWRs
Technical Report
·
Sat Sep 01 00:00:00 EDT 1984
·
OSTI ID:6428127
Forced outage assessment for the MHTGR [Modular High-Temperature Gas-Cooled Reactor]
Technical Report
·
Wed Jul 01 00:00:00 EDT 1987
·
OSTI ID:714095
Analysis of risk reduction methods for interfacing system LOCAs (loss-of-coolant accidents) at PWRs
Conference
·
Thu Dec 31 23:00:00 EST 1987
·
OSTI ID:6968283
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210300 -- Power Reactors
Nonbreeding
Graphite Moderated
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BOILERS
CLEANING
COOLING SYSTEMS
DECONTAMINATION
ELECTRIC GENERATORS
ENERGY SYSTEMS
FISSION PRODUCT RELEASE
GAS COOLED REACTORS
GRAPHITE MODERATED REACTORS
HTGR TYPE REACTORS
LEAKS
PRIMARY COOLANT CIRCUITS
REACTOR ACCIDENTS
REACTOR COMPONENTS
REACTOR COOLING SYSTEMS
REACTOR SAFETY
REACTORS
RISK ASSESSMENT
SAFETY
STEAM GENERATORS
TURBOGENERATORS
VAPOR GENERATORS
210300 -- Power Reactors
Nonbreeding
Graphite Moderated
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BOILERS
CLEANING
COOLING SYSTEMS
DECONTAMINATION
ELECTRIC GENERATORS
ENERGY SYSTEMS
FISSION PRODUCT RELEASE
GAS COOLED REACTORS
GRAPHITE MODERATED REACTORS
HTGR TYPE REACTORS
LEAKS
PRIMARY COOLANT CIRCUITS
REACTOR ACCIDENTS
REACTOR COMPONENTS
REACTOR COOLING SYSTEMS
REACTOR SAFETY
REACTORS
RISK ASSESSMENT
SAFETY
STEAM GENERATORS
TURBOGENERATORS
VAPOR GENERATORS