An x-ray fluorescence microprobe (XRM) for trace element analysis is in operation at the National Synchrotron Light Source of Brookhaven National Laboratory. The properties of synchrotron radiation, in this case a continuous spectrum of x rays ranging up to 40 keV, make possible its uses as a microprobe beam with collimation or focusing with appropriate optical elements. Sensitivities in thin samples at 10 /times/ 10 /mu/m/sup 2/ spatial resolution is of the order of 10 fg using filtered, collimated ''white light'' and about 3 fg using a Kirkpatrick-Baez (KB) focusing system in thin standard foil. Results using a newly installed ellipsoidal mirror will be described. A discussion of standards for microprobe analysis is included. Examples of applications to the life sciences are described. These include the mapping of trace element distributions in thin tissue samples and examples of transmission and fluorescence microtomography. Synchrotron radiation microprobes complement ion and electron beam microprobes and the differences between the methods are considered. 23 figs., 4 tabs.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 5708785
- Report Number(s):
- BNL-43048; CONF-8906161-6; ON: DE89017622
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurement of femtogram quantities of trace elements using an x-ray microprobe
An x-ray microprobe facility using synchrotron radiation
Design criteria and sensitivity calculations for multielemental trace analysis at the NSLS x-ray microprobe
Journal Article
·
Sun May 01 00:00:00 EDT 1988
· Anal. Chem.; (United States)
·
OSTI ID:6862402
An x-ray microprobe facility using synchrotron radiation
Conference
·
Sat Dec 31 23:00:00 EST 1988
·
OSTI ID:6263258
Design criteria and sensitivity calculations for multielemental trace analysis at the NSLS x-ray microprobe
Conference
·
Sat Dec 31 23:00:00 EST 1983
·
OSTI ID:6241856
Related Subjects
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY
400102* -- Chemical & Spectral Procedures
550200 -- Biochemistry
59 BASIC BIOLOGICAL SCIENCES
ACCELERATORS
BIOLOGICAL MATERIALS
BREMSSTRAHLUNG
CHEMICAL ANALYSIS
CYCLIC ACCELERATORS
ELECTROMAGNETIC RADIATION
MATERIALS
MEASURING INSTRUMENTS
NONDESTRUCTIVE ANALYSIS
NSLS
PROBES
QUANTITATIVE CHEMICAL ANALYSIS
RADIATION SOURCES
RADIATIONS
SYNCHROTRON RADIATION
SYNCHROTRON RADIATION SOURCES
SYNCHROTRONS
TECHNOLOGY ASSESSMENT
TRACE AMOUNTS
X-RAY EMISSION ANALYSIS
X-RAY FLUORESCENCE ANALYSIS
400102* -- Chemical & Spectral Procedures
550200 -- Biochemistry
59 BASIC BIOLOGICAL SCIENCES
ACCELERATORS
BIOLOGICAL MATERIALS
BREMSSTRAHLUNG
CHEMICAL ANALYSIS
CYCLIC ACCELERATORS
ELECTROMAGNETIC RADIATION
MATERIALS
MEASURING INSTRUMENTS
NONDESTRUCTIVE ANALYSIS
NSLS
PROBES
QUANTITATIVE CHEMICAL ANALYSIS
RADIATION SOURCES
RADIATIONS
SYNCHROTRON RADIATION
SYNCHROTRON RADIATION SOURCES
SYNCHROTRONS
TECHNOLOGY ASSESSMENT
TRACE AMOUNTS
X-RAY EMISSION ANALYSIS
X-RAY FLUORESCENCE ANALYSIS