Cathodic protection retrofit of an offshore pipeline

Journal Article · · Materials Performance
OSTI ID:566699
;  [1]
  1. Tenneco Energy, Houston, TX (United States)

Cathodic protection (CP) anodes and corrosion coating on two offshore pipelines were damaged during deep water installation. In-situ methods for deep-water inspection and repair of the pipelines` CP and coating systems were developed and used. High-pressure natural gas Pipeline. A design was 5.6 miles of 8.625 in. OD by 0.406 in. W.T. API SL, Grade X-42, seamless line pipe. Pipeline B design was 0.3 miles of similar specification pipe. Both pipelines were mill-coated with 14 mil of fusion-bonded epoxy (FBE) corrosion coating. Girth welds were field-coated with FBE.

OSTI ID:
566699
Journal Information:
Materials Performance, Journal Name: Materials Performance Journal Issue: 9 Vol. 36; ISSN MTPFBI; ISSN 0094-1492
Country of Publication:
United States
Language:
English

Similar Records

Cathodic protection retrofit of an offshore pipeline
Conference · Mon Sep 01 00:00:00 EDT 1997 · OSTI ID:511999

Offshore pipeline costs skyrocket
Journal Article · Fri Oct 01 00:00:00 EDT 1976 · Pipe Line Ind.; (United States) · OSTI ID:7014561

The use of coatings to supplement cathodic protection of offshore structures
Journal Article · Sat Oct 31 23:00:00 EST 1987 · Mater. Performance; (United States) · OSTI ID:5394145