Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Physical test report to drop test of a 9975 radioactive material shipping packaging

Technical Report ·
DOI:https://doi.org/10.2172/565502· OSTI ID:565502

This report presents the drop test results for the 9975 radioactive material shipping package being dropped 30 feet onto a unyielding surface followed by a 40-inch puncture pin drop. The purpose of these drops was to show that the package lid would remain attached to the drum. The 30-foot drop was designed to weaken the lid closure lug while still maintaining maximum extension of the lugs from the drum surface. This was accomplished by angling the drum approximately 30 degrees from horizontal in an inverted position. In this position, the drum was rotated slightly so as not to embed the closure lugs into the drum as a result of the 30-foot drop. It was determined that this orientation would maximize deformation to the closure ring around the closure lug while still maintaining the extension of the lugs from the package surface. The second drop was from 40 inches above a 40-inch tall 6-inch diameter puncture pin. The package was angled 10 degrees from vertical and aligned over the puncture pin to solidly hit the drum lug(s) in an attempt to disengage the lid when dropped.Tests were performed in response to DOE EM-76 review Q5 inquires that questioned the capability of the 9975 drum lid to remain in place under this test sequence. Two packages were dropped utilizing this sequence, a 9974 and 9975. Test results for the 9974 package are reported in WSRC-RP-97-00945. A series of 40-inch puncture pin tests were also performed on undamaged 9975 and 9974 packages.

Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
565502
Report Number(s):
WSRC-RP--97-00944; ON: DE98050695
Country of Publication:
United States
Language:
English

Similar Records

Physical test report for drop test of a 9974 radioactive material shipping packaging
Technical Report · Wed Oct 01 00:00:00 EDT 1997 · OSTI ID:565168

Drop tests of the redesigned 9975 package June 2000
Technical Report · Thu Jun 01 00:00:00 EDT 2000 · OSTI ID:1169583

Responses of Conventional Ring Closures of Drum Type Packages to Regulatory Drop Tests with Application to the 9974/9975 Package
Conference · Fri May 31 00:00:00 EDT 2002 · OSTI ID:799401