Physical test report for drop test of a 9974 radioactive material shipping packaging
- Westinghouse Savannah River Company, AIKEN, SC (United States)
This report presents the drop test results for the 9974 radioactive material shipping package being dropped onto 6-inch diameter, 40-inch long puncture pin. Also reported are the drop test resuls for a 30-foot impact that failed the drum confinement boundary. The purpose of these drops was to show that the package lid would remain attached to the drum.
- Research Organization:
- Westinghouse Savannah River Co., Aiken, SC (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 565168
- Report Number(s):
- WSRC-RP--97-00945; ON: DE98050694
- Country of Publication:
- United States
- Language:
- English
Similar Records
Physical test report to drop test of a 9975 radioactive material shipping packaging
DropTests of 325 Pound 6M Packages
FINITE ELEMENT ANALYSIS OF BULK TRITIUM SHIPPING PACKAGE
Technical Report
·
Mon Nov 10 23:00:00 EST 1997
·
OSTI ID:565502
DropTests of 325 Pound 6M Packages
Technical Report
·
Thu Jan 29 23:00:00 EST 2004
·
OSTI ID:821284
FINITE ELEMENT ANALYSIS OF BULK TRITIUM SHIPPING PACKAGE
Conference
·
Wed Jun 02 00:00:00 EDT 2010
·
OSTI ID:981653