(Demonstration of refrigeration: waste heat recovery in floriculture. ) Final report
Technical Report
·
OSTI ID:5653474
This project demonstrated successful operation economically over a one year period when a savings of $3208 in electric power and natural gas heating costs indicated a payback period of 3 years. The installation used conventional refrigeration and building materials. (PSB)
- Research Organization:
- Flowers by Ford, Inc., Penns Grove, NJ (USA)
- DOE Contract Number:
- FG42-80R205121
- OSTI ID:
- 5653474
- Report Number(s):
- DOE/R2/05121-T1; ON: DE85015649
- Country of Publication:
- United States
- Language:
- English
Similar Records
Low cost owner installed domestic solar water heater demonstration. Final report
Heat recovery pinched by rising costs, payback
Heat recovery from a fume-gas incinerator. Final report
Technical Report
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5501126
Heat recovery pinched by rising costs, payback
Journal Article
·
Mon Oct 09 00:00:00 EDT 1978
· Energy User News; (United States)
·
OSTI ID:6785540
Heat recovery from a fume-gas incinerator. Final report
Technical Report
·
Mon Dec 14 23:00:00 EST 1987
·
OSTI ID:6337907
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320304* -- Energy Conservation
Consumption
& Utilization-- Industrial & Agricultural Processes-- Waste Heat Recovery & Utilization
BUILDINGS
ENERGY CONSERVATION
FEASIBILITY STUDIES
GREENHOUSES
OPERATION
ORNAMENTAL PLANTS
PLANTS
POLLUTION
POLLUTION ABATEMENT
THERMAL POLLUTION
WASTE HEAT UTILIZATION
WASTE PRODUCT UTILIZATION
WATER REQUIREMENTS
320304* -- Energy Conservation
Consumption
& Utilization-- Industrial & Agricultural Processes-- Waste Heat Recovery & Utilization
BUILDINGS
ENERGY CONSERVATION
FEASIBILITY STUDIES
GREENHOUSES
OPERATION
ORNAMENTAL PLANTS
PLANTS
POLLUTION
POLLUTION ABATEMENT
THERMAL POLLUTION
WASTE HEAT UTILIZATION
WASTE PRODUCT UTILIZATION
WATER REQUIREMENTS