Applicability of superheated drop (bubble) detectors to reactor dosimetry

Conference ·
OSTI ID:55590
;  [1];  [2]; ;  [3]
  1. Univ. degli Studi di Pisa (Italy). Dipt. di Costruzioni Meccaniche e Nucleari
  2. Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)
  3. Yale Univ., New Haven, CT (United States). Dept. of Mechanical Engineering

The characteristics of superheated drop (bubble) detectors (SDD`s) have been reviewed with respect to the possible application of these devices in reactor dosimetry. In particular, their ability to measure neutrons in the presence of a high noise level, elevated temperatures and intense {gamma} background has been investigated. Based on these studies, the use of SDD`s is proposed for the monitoring and analysis of neutron emission from spent fuel assemblies. Finally, the possibility to employ these detectors in radiation protection dosimetry around power plants is discussed.