Transmission-corrected x-ray fluorescence analysis of uranium and plutonium solutions using a dual transmission source

Conference ·
OSTI ID:5539056
The energy-dispersive x-ray fluorescence analysis (XRFA) technique has been implemented at several spent nuclear fuel reprocessing facilities for nondestructive measurements of uranium and/or plutonium concentrations in process streams and product storage tanks. An important factor in these quantitative measurements is the absorption of the fluoresced x-rays by the solution matrix, which must be taken into account to accurately quantify the U or Pu concentrations. We describe a new, accurate method using a dual transmission source of Gd-153 and Co-57 to correct for matrix effects. Results of measurements on uranium and plutonium solution standards show the methodology to be better than 0.5%, which includes statistical precision, over the concentration range from 1 to 250 g/l. 5 refs., 4 figs., 3 tabs.
Research Organization:
Lawrence Livermore National Lab., CA (USA)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5539056
Report Number(s):
UCRL-96685; CONF-871110-14; ON: DE88003997
Country of Publication:
United States
Language:
English

Similar Records

Transmission-corrected x-ray fluorescence analysis of uranium and plutonium solutions using a dual transmission source
Conference · Wed Dec 31 23:00:00 EST 1986 · Transactions of the American Nuclear Society; (USA) · OSTI ID:5693148

A transportable x-ray fluorescence analysis system for assay of plutonium and uranium solutions in gloveboxes
Conference · Fri Jun 01 00:00:00 EDT 1990 · OSTI ID:6683326

Uranium and plutonium solution assays by transmission-corrected x-ray fluorescence
Conference · Wed Sep 08 00:00:00 EDT 1999 · OSTI ID:14872