Energy conservation and acceptable indoor air quality in the classroom
Journal Article
·
· ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States)
OSTI ID:5531763
- Wheeler Engineering, Towson, MD (US)
The Ventilation Rate Procedure, as found in ASHRAE Standard 62-1989, increases outdoor air ventilation rates over the previous standard for many applications. Few are likely to be affected more decidedly than the school classroom. When the standard's estimated maximum occupancy is combined with the ventilation rate, the outdoor air supply to a classroom is 0.75 cfm per ft{sup 2} of floor space. This rate can be more than half of the total air supply needed for cooling. Moreover, this rate is also the minimum permissible total air flow as well as the outdoor air component. Thus, variable air volume (VAV) terminals are limited to a 2:1 turndown ratio or less. To avoid overcooling when cooling loads are less than 50% of design, reheat is necessary. In most American climates, preheat will also be required. Consternation over increased energy use and heating and cooling capacity requirements for schools appears to be well-founded. This paper reports that to analyze this concern, national and state statistical data describing class size and other parameters were examined. In addition, characteristics of general studies classrooms and the HVAC systems that serve them were surveyed in Maryland public elementary and secondary schools.
- OSTI ID:
- 5531763
- Journal Information:
- ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States), Journal Name: ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States) Vol. 34:4; ISSN ASHRA; ISSN 0001-2491
- Country of Publication:
- United States
- Language:
- English
Similar Records
Investigation of VOCs and PM{sub 2.5} concentrations at two classrooms with or without air conditioning in Hong Kong
Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms
Indoor air quality and energy-efficiency ventilation rates at a New York City elementary school
Conference
·
Thu Jul 01 00:00:00 EDT 1999
·
OSTI ID:20003311
Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms
Technical Report
·
Fri Apr 04 00:00:00 EDT 2008
·
OSTI ID:927880
Indoor air quality and energy-efficiency ventilation rates at a New York City elementary school
Technical Report
·
Fri May 01 00:00:00 EDT 1981
·
OSTI ID:6471356
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
AIR QUALITY
COOLING
DATA
DEVELOPED COUNTRIES
EDUCATIONAL FACILITIES
ENERGY CONSERVATION
ENVIRONMENTAL QUALITY
INFORMATION
MARYLAND
NORTH AMERICA
NUMERICAL DATA
RECOMMENDATIONS
SPACE HVAC SYSTEMS
STATISTICAL DATA
SURVEYS
USA
VENTILATION
VENTILATION SYSTEMS
VOLUME
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
AIR QUALITY
COOLING
DATA
DEVELOPED COUNTRIES
EDUCATIONAL FACILITIES
ENERGY CONSERVATION
ENVIRONMENTAL QUALITY
INFORMATION
MARYLAND
NORTH AMERICA
NUMERICAL DATA
RECOMMENDATIONS
SPACE HVAC SYSTEMS
STATISTICAL DATA
SURVEYS
USA
VENTILATION
VENTILATION SYSTEMS
VOLUME