Title: SRL canister impact tests

Technical Report ·
OSTI ID:5512978

The Defense Waste Processing Facility (DWPF) is being constructed at the SRP for the containerization of high-level nuclear waste as a waste form for eventual permanent disposal. The waste will be incorporated in molten glass and solidified in Type 304L stainless steel canisters 2 feet in diameter x 9 feet 10 inches long. The canisters have a minimum wall thickness of 3/8 inch. Over a three-year period, nineteen drop-tests of nine canisters, filled with simulated waste glass, were made in support of the DWPF containerization program. Eight of the canister evaluation tests were of Type 304L stainless steel material and one was of commercially pure titanium. Three different length (9.44, 5.06, and 7.88 inch) nozzle configurations containing final closure upset welds were evaluated for the stainless steel canisters. All impact tests of the stainless steel canisters, which included bottom-, side-, and top-drops, were acceptable. The bottom-drop test of the titanium canister, which contained a final closure upset weld, was acceptable; however, the top-drop resulted in a breaching of the top head where it joins the nozzle. The final closure titanium upset weld was acceptable. The titanium canister wall thickness was 1/4 inch.

Research Organization:
Du Pont de Nemours (E.I.) and Co., Aiken, SC (USA). Savannah River Lab.
DOE Contract Number:
AC09-76SR00001
OSTI ID:
5512978
Report Number(s):
DP-1716; ON: DE86012766
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English