Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

X-ray holographic microscopy experiments at the Brookhaven synchrotron light source

Journal Article · · Proc. Soc. Photo-Opt. Instrum. Eng.; (United States)
DOI:https://doi.org/10.1117/12.939199· OSTI ID:5499032
Soft x-ray holographic microscopy is discussed from an experimental point of view. Three series of measurements have been carried out using the Brookhaven 750 MeV storage ring as an x-ray source. Young slits fringes, Gabor (in line) holograms and various data measurements are discussed in terms of the technique for recording them and the experimental limitations in effect. Some discussion is also given of the issues involved in reconstruction using visible light. 19 references, 12 figures, 1 table.
Research Organization:
Brookhaven National Lab., Upton, NY
OSTI ID:
5499032
Journal Information:
Proc. Soc. Photo-Opt. Instrum. Eng.; (United States), Journal Name: Proc. Soc. Photo-Opt. Instrum. Eng.; (United States) Vol. 447; ISSN SPIEC
Country of Publication:
United States
Language:
English