Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Critical comparison of soft x-ray fluorescence detectors for XAFS studies in the 2 to 4 keV region

Conference ·
OSTI ID:5480447
;  [1]
  1. Brookhaven National Lab., Upton, NY (USA)
We report a performance comparison of fluorescence detectors for XAFS in the soft x-ray region. In particular this comparison was made under the practical constraints of an existing hard x-ray beamline (X-19A NSLS) double Si(111) crystal monochromator with a 10 mil beryllium exit window. A critical comparison of an energy dispersive proportional counter and an ionization chamber was performed above the sulfur K edge for a very dilute sample and a mixed element system. Third harmonic contributions and signal to background are discussed with the conclusion that an energy dispersive proportional counter provides superior results under our beamline constraints. 7 refs., 4 figs.
Research Organization:
Brookhaven National Lab., Upton, NY (USA)
Sponsoring Organization:
DOE/ER
DOE Contract Number:
AC02-76CH00016
OSTI ID:
5480447
Report Number(s):
BNL-43316; CONF-890802--3; ON: DE90001559
Country of Publication:
United States
Language:
English