Guyed tower design and analysis. Part 3. Preliminary calculation procedures

Journal Article · · Pet. Eng. Int.; (United States)
OSTI ID:5431875
Realistic design of deepwater guyed-tower platforms must include calculations of structural compliant motion, structural deflections (called P-delta effects), cable response, and foundation nonlinearities. These nonlinear requirements call for knowledge of the actual force history on the structure rather than an instantaneous maximum design force distribution on the structure, thus greatly complicating and expanding the design process. Part 3 covers the preliminary static, preliminary guy, and modal analyses involved in designing the towers.
Research Organization:
Conoco Inc.
OSTI ID:
5431875
Journal Information:
Pet. Eng. Int.; (United States), Journal Name: Pet. Eng. Int.; (United States) Vol. 53; ISSN PEEID
Country of Publication:
United States
Language:
English

Similar Records

Guyed tower design and analysis. Part 2. Static analysis of preliminary guy design
Journal Article · Sat Nov 14 23:00:00 EST 1981 · Pet. Eng. Int.; (United States) · OSTI ID:5670137

Guyed tower design and analysis. Part 1. The concept
Journal Article · Sat Oct 31 23:00:00 EST 1981 · Pet. Eng. Int.; (United States) · OSTI ID:5544310

Low frequency drift oscillation of offshore guyed towers