Potential energy savings in residential oil-fired heating systems in the US
Technical Report
·
OSTI ID:5428859
Studies of the performance of residential oil-fired heating systems in the New England area from 1974 to 1977 demonstrated that significant energy savings are achievable through better maintenance and simple system modifications. These studies showed that annual tune-up of the furnace or boiler would improve the seasonal efficiency of most units, while considerable energy savings are possible by reducing the firing rate of the burner. Reduction in nozzle size with burner modification or with the installation of a new flame retention burner was found to reduce oil consumption substantially. In addition, more innovative equipment modifications such as the use of stack dampers, sealed combustion systems, and heat recovery devices also resulted in fuel savings, although to a lesser extent. Both experimental field data and results from computer simulations of furnace performance are presented. 22 refs., 7 figs., 17 tabs.
- Research Organization:
- National Bureau of Standards, Washington, DC (USA). Center for Building Technology
- OSTI ID:
- 5428859
- Report Number(s):
- NBS-BSS-163; ON: TI85901698
- Country of Publication:
- United States
- Language:
- English
Similar Records
Interim guidance for oil heating equipment selection for naval residential housing. Report for Sep 82-Oct 83
Field tests of refit equipment for residential oil-fired heating systems
Oil burner retrofit to save energy and reduce emissions. Paper 81. 8. 1
Technical Report
·
Sat Dec 31 23:00:00 EST 1983
·
OSTI ID:6790812
Field tests of refit equipment for residential oil-fired heating systems
Technical Report
·
Wed Mar 31 23:00:00 EST 1982
·
OSTI ID:5089777
Oil burner retrofit to save energy and reduce emissions. Paper 81. 8. 1
Conference
·
Wed Dec 31 23:00:00 EST 1980
· Proc., Annu. Meet., Air Pollut. Control Assoc.; (United States)
·
OSTI ID:6485269
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
BUILDINGS
BURNERS
COMPUTERIZED SIMULATION
CONTROL EQUIPMENT
DATA
DRAFT CONTROL SYSTEMS
EFFICIENCY
ENERGY CONSERVATION
ENERGY EFFICIENCY
ENERGY RECOVERY
ENERGY SYSTEMS
EQUIPMENT
EXPERIMENTAL DATA
FEDERAL REGION I
FIELD TESTS
FLOW REGULATORS
FURNACES
HEAT RECOVERY
HEATING SYSTEMS
INFORMATION
MAINTENANCE
MODIFICATIONS
NORTH AMERICA
NOZZLES
NUMERICAL DATA
OIL FURNACES
RECOVERY
RESIDENTIAL BUILDINGS
SIMULATION
TESTING
USA
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
BUILDINGS
BURNERS
COMPUTERIZED SIMULATION
CONTROL EQUIPMENT
DATA
DRAFT CONTROL SYSTEMS
EFFICIENCY
ENERGY CONSERVATION
ENERGY EFFICIENCY
ENERGY RECOVERY
ENERGY SYSTEMS
EQUIPMENT
EXPERIMENTAL DATA
FEDERAL REGION I
FIELD TESTS
FLOW REGULATORS
FURNACES
HEAT RECOVERY
HEATING SYSTEMS
INFORMATION
MAINTENANCE
MODIFICATIONS
NORTH AMERICA
NOZZLES
NUMERICAL DATA
OIL FURNACES
RECOVERY
RESIDENTIAL BUILDINGS
SIMULATION
TESTING
USA