Effects of cesium in the plasma of the surface conversion H/sup -/ source

Conference ·
OSTI ID:5419594
The usual method for replacing the partial monolayer of cesium which is removed by sputtering from the surface of the converter electrode of a surface production negative ion source, is to allow cesium atoms to condense or adsorb onto this surface. While this method is easily employed for short pulsed source operation, it becomes increasingly difficult in the dc case because of the high probability of ionization of the cesium atoms as they pass through the discharge. In this paper, we attempt to analyze the severity of this problem in which cesium arrives at the converter surface as an energetic ion rather than as a thermal atom.
Research Organization:
Lawrence Berkeley Lab., CA (USA)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
5419594
Report Number(s):
LBL-16865; CONF-831180-17; ON: DE84003388
Country of Publication:
United States
Language:
English

Similar Records

Effects of cesium in the plasma of the surface conversion H/sup -/ source
Journal Article · Wed Feb 29 23:00:00 EST 1984 · AIP Conf. Proc.; (United States) · OSTI ID:5679681

Modeling of H sup minus surface conversion sources; binary (H-Ba) and ternary (H-Cs/W) converter arrangements
Journal Article · Sun Sep 01 00:00:00 EDT 1991 · Journal of Applied Physics; (United States) · OSTI ID:5251865

Direct measurement of cesium absorption isobars on polycrystalline tantalum
Journal Article · Sat Dec 31 23:00:00 EST 1977 · J. Appl. Phys.; (United States) · OSTI ID:5348090