Fluidized-bed combustion: effectiveness of an SO/sub 2/ control technology for industrial boilers. Final report

Technical Report ·
OSTI ID:5418105
Atmospheric fluidized-bed combustion (AFBC) boilers have developed rapidly over recent years and are now offered commercially in several different configurations. SO/sub 2/ reduction levels of 90% and above have been achieved by coal-fired AFBC boilers in the industrial size category. Based on the data available, industrial FBC NOx emissions have been consistently below 0.5 lb/million Btu. PM emissions of less than 0.5 lb/million Btu have been routinely achieved with fabric filters. AFBC boiler system costs were compared with costs for a conventional boiler equipped with an FGD system and with costs for a conventional boiler using low-sulfur compliance coal. The conclusions drawn from the economic analyses are that (1) studied cost difference between AFBC Technology, conventional boiler/FGD systems, and compliance coal combustion are projected to be small over the SO/sub 2/ emission range of 1.7 to 0.8 lb/million Btu and SO/sub 2/ reduction range of 65 to 90%, and (2) that cost competitiveness among these technologies is not expected to change significantly as the emission limitations change over this range. Absolute economic competitiveness among these options will be sensitive to site-specific parameters and decided on a case-by-case basis.
Research Organization:
Radian Corp., Research Triangle Park, NC (USA)
OSTI ID:
5418105
Report Number(s):
PB-85-197101/XAB
Country of Publication:
United States
Language:
English