Comparisons of TRAC-PF-1 calculations with semiscale Mod-3 small-break tests S-SB-P1 and S-SB-P7. [PWR]

Conference ·
OSTI ID:5338199
Semiscale Tests S-SB-P1 and S-SB-P7 conducted in the Semiscale Mod-3 facility at the Idaho National Engineering Laboratory are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1). The results are used to assess TRAC-PF1 predictions of thermal-hydraulic phenomena and the effects of break size and pump operation on system response during slow transients. Tests S-SB-P1 and S-SB-P7 simulated an equivalent pressurized-water-reactor (PWR) 2.5% communicative cold-leg break for early and late pump trips, respectively, with only high-pressure injection (HPI) into the cold legs. The parameters examined include break flow, primary-system pressure response, primary-system mass distribution, and core characteristics.