Siting-selection study for the Soyland Power Cooperative, Inc. , compressed-air energy-storage system (CAES)
A method used for siting a compressed air energy storage (CAES) system using geotechnical and environmental criteria is explained using the siting of a proposed 220 MW water-compensated CAES plant in Illinois as an example. Information is included on the identification and comparative ranking of 28 geotechnically and environmental sites in Illinois, the examination of fatal flaws, e.g., mitigation, intensive studies, costly studies, permit denials, at 7 sites; and the selection of 3 sites for further geological surveying. (LCL)
- Research Organization:
- Pacific Northwest Lab., Richland, WA (USA)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 5328133
- Report Number(s):
- PNL-4078; ON: DE82008766
- Country of Publication:
- United States
- Language:
- English
Similar Records
Technology assessment report for the Soyland Power Cooperative, Inc. compressed air energy storage system (CAES)
Compressed Air Energy Storage preliminary design and site development program in an aquifer. Final report. Site selection study, Part 1
Siting compressed-air energy storage plants
Technical Report
·
Thu Dec 31 23:00:00 EST 1981
·
OSTI ID:5561401
Compressed Air Energy Storage preliminary design and site development program in an aquifer. Final report. Site selection study, Part 1
Technical Report
·
Fri Jul 31 00:00:00 EDT 1981
·
OSTI ID:5831470
Siting compressed-air energy storage plants
Conference
·
Sun Dec 31 23:00:00 EST 1989
· Proceedings of the American Power Conference; (United States)
·
OSTI ID:6368345