Stress analysis of the modified Pulsed Neutron Activation system downstream shield support structure

Technical Report ·
DOI:https://doi.org/10.2172/5261046· OSTI ID:5261046
The modified LOFT Pulsed Neutron Activation (PNA) System downstream shielding support structure was stress analyzed for deadweight and worst-case LOCE loads. No deficiencies were found in the structure. This stress analysis was performed for the PNA Shielding Configuration that has been used on Test L3-2 and that is to be used on Test L3-7.