Solar Pilot Plant, Phase 1. Detailed design report: steam generator subsystem research experiment
The steam generator test item, test facility, and test equipment for the solar pilot plant in Barstow are presented. The experiment's objective is to validate the base line design of the steam generator, and to minimize high risk issues. The general characteristics of the steam generator, and the detailed design of the major components are described and illustrated. A steady-state functional performance analysis is presented that makes use of design methods to configure the steam generator and to provide design and operating criteria. Also, a transient analysis was performed which considered cold startup, hot startup, heat input ramp, and cloud disturbance. A stress analysis was performed to verify structural adequacy of the steam generator. The test facility to be used and the test plans and schedules are described. (LEW)
- Research Organization:
- Honeywell, Inc., Minneapolis, MN (USA). Systems and Research Center
- DOE Contract Number:
- AC03-76SF11109
- OSTI ID:
- 5248796
- Report Number(s):
- DOE/SF/11109-T13; ON: DE82005372
- Country of Publication:
- United States
- Language:
- English
Similar Records
Solar Pilot Plant Phase I, detailed design report: collector subsystem research experiment. CDRL Item No. 6 (Approved)
Solar pilot plant, Phase 1. Quarterly report No. 6, January-March 1977
Related Subjects
140702* -- Solar Thermal Power Systems-- Central Receiver
ANALOG SYSTEMS
BARSTOW SOLAR PILOT PLANT
BOILERS
CENTRAL RECEIVERS
DATA ACQUISITION SYSTEMS
DESIGN
DIAGRAMS
EQUIPMENT
FLOWSHEETS
FUNCTIONAL MODELS
MATHEMATICAL MODELS
MECHANICAL STRUCTURES
OPERATION
PERFORMANCE
PILOT PLANTS
POWER PLANTS
SIMULATORS
SOLAR EQUIPMENT
SOLAR POWER PLANTS
SOLAR RECEIVERS
SOLAR SIMULATORS
SOLAR THERMAL POWER PLANTS
STEADY-STATE CONDITIONS
STEAM GENERATORS
STRESS ANALYSIS
SUPERHEATERS
SUPPORTS
TEST FACILITIES
TESTING
THERMAL POWER PLANTS
TOWER FOCUS POWER PLANTS
TRANSIENTS
VAPOR GENERATORS