In vitro and in vivo studies of the TRIUMF pion therapy beam
Journal Article
·
· Radiat. Res., Suppl.; (United States)
Patient treatments at TRIUMF (Tri-University Meson Facility, Vancouver, B. C.) use a moving spot raster scan technique where the pion range is modulated in depth for each position of the moving spot. The spot scans in a stepwise fashion and can produce any desired field shape. This approach provides very good dose uniformity across the treatment field and allows maximum flexibility in shaping the treatment volume. Survival of cultured cells has been used as a biological dosimeter to test the isoeffectiveness of the pion dose distributions, which must be shaped in depth to compensate for the depth-dependent LET distribution. Isoeffectiveness across the treatment field has also been verified using this system, which involves irradiating cells supported in a gelatin matrix. The response of pig skin to pion irradiation at TRIUMF has provided a check on the in vivo RBE for acute effects derived from our earlier studies with mouse foot. In addition, the pig skin reactions have been followed for several months to assess the later dermal response. The RBE of our pion beam relative to 270 kVp X rays is approximately 1.5 for both the acute epidermal and the later dermal responses.
- Research Organization:
- Mount Vernon Hospital, England
- OSTI ID:
- 5204898
- Journal Information:
- Radiat. Res., Suppl.; (United States), Journal Name: Radiat. Res., Suppl.; (United States); ISSN RARSA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Radiobiology of pions at TRIUMF
Pions and pig skin: preclinical evaluation of RBE for early and late damage
Beam scanning system for a clinical pi-meson beam
Journal Article
·
Tue Nov 30 23:00:00 EST 1982
· Int. J. Radiat. Oncol., Biol. Phys.; (United States)
·
OSTI ID:5477121
Pions and pig skin: preclinical evaluation of RBE for early and late damage
Journal Article
·
Fri Jan 31 23:00:00 EST 1986
· Int. J. Radiat. Oncol., Biol. Phys.; (United States)
·
OSTI ID:5737806
Beam scanning system for a clinical pi-meson beam
Journal Article
·
Fri Feb 28 23:00:00 EST 1986
· Rev. Sci. Instrum.; (United States)
·
OSTI ID:6288871
Related Subjects
550603* -- Medicine-- External Radiation in Therapy-- (1980-)
62 RADIOLOGY AND NUCLEAR MEDICINE
ANIMALS
BEAMS
BODY
DOMESTIC ANIMALS
DOSIMETRY
ELEMENTARY PARTICLES
ENERGY TRANSFER
HAMSTERS
LET
MAMMALS
MEDICINE
MESON BEAMS
NUCLEAR MEDICINE
ORGANS
PARTICLE BEAMS
PION BEAMS
RADIATION DOSE DISTRIBUTIONS
RADIOLOGY
RADIOTHERAPY
RBE
RODENTS
SKIN
SWINE
THERAPY
VERTEBRATES
62 RADIOLOGY AND NUCLEAR MEDICINE
ANIMALS
BEAMS
BODY
DOMESTIC ANIMALS
DOSIMETRY
ELEMENTARY PARTICLES
ENERGY TRANSFER
HAMSTERS
LET
MAMMALS
MEDICINE
MESON BEAMS
NUCLEAR MEDICINE
ORGANS
PARTICLE BEAMS
PION BEAMS
RADIATION DOSE DISTRIBUTIONS
RADIOLOGY
RADIOTHERAPY
RBE
RODENTS
SKIN
SWINE
THERAPY
VERTEBRATES