Evaluation and test of improved fire-resistant fluid lubricants for water reactor coolant pump motors. Volume 2. Fluid/metal compatibility
Fires within nuclear containment have occurred when the lubricants used in reactor coolant pump motors have leaked or spilled onto the hot insulated main coolant piping. This project was directed toward determining the applicability of commercially available fire resistant fluid lubricants to the lubrication of the bearings of a reactor coolant pump motor. This report describes the evaluation of candidate fluids, the testing of these fluids, and the selection of a lubricant for use in a standard reactor coolant pump motor test. The test results indicated that the phsophate ester lubricants, when properly inhibited and maintained, are acceptable for use. Recommendations are presented for further work necessary to the successful application of the fire resistant fluid lubricant.
- Research Organization:
- Westinghouse Electric Corp., East Pittsburgh, PA (USA). Steam Turbine Generator Technical Operations Div.
- OSTI ID:
- 5194795
- Report Number(s):
- EPRI-NP-1447(Vol.2)
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation and test of improved fire-resistant fluid lubricants for water reactor coolant pump motors. Volume 1. Fluid evaluation, bearing model tests, motor tests, and fire tests
Remote detection of degradation of fire-resistant fluid lubricants. [PWR]
Fire-retardant lubricant for turbine generators. Final report. [PWR]
Technical Report
·
Tue Jul 01 00:00:00 EDT 1980
·
OSTI ID:5194794
Remote detection of degradation of fire-resistant fluid lubricants. [PWR]
Technical Report
·
Sun Aug 01 00:00:00 EDT 1982
·
OSTI ID:5043316
Fire-retardant lubricant for turbine generators. Final report. [PWR]
Technical Report
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:6470141
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210100* -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
210200 -- Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
BWR TYPE REACTORS
COMPARATIVE EVALUATIONS
COMPATIBILITY
COOLING SYSTEMS
ELECTRIC MOTORS
FIRE RESISTANCE
LUBRICANTS
MATERIALS
MOTORS
PERFORMANCE
PRIMARY COOLANT CIRCUITS
PUMPS
PWR TYPE REACTORS
REACTOR COMPONENTS
REACTOR COOLING SYSTEMS
REACTOR MATERIALS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210100* -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
210200 -- Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
BWR TYPE REACTORS
COMPARATIVE EVALUATIONS
COMPATIBILITY
COOLING SYSTEMS
ELECTRIC MOTORS
FIRE RESISTANCE
LUBRICANTS
MATERIALS
MOTORS
PERFORMANCE
PRIMARY COOLANT CIRCUITS
PUMPS
PWR TYPE REACTORS
REACTOR COMPONENTS
REACTOR COOLING SYSTEMS
REACTOR MATERIALS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS