25-channel time-to-digit converter

Journal Article · · Instrum. Exp. Tech. (Engl. Transl.); (United States)
OSTI ID:5155050
This paper describes a 25-channel time-to-digit converter for measurement of time delays of particles in extensive air showers of cosmic rays. The range of time-interval measurement is 150 nsec to 6.4 ..mu..sec. The measurement accuracy is 3.8 nsec for an integral nonlinearity of ca 0.1%. The temperature bability is 2.10/sup -4/ h/sup -1/.
Research Organization:
Sci-Res. Institute of Nuclear Physics, Moscow State Univ.
OSTI ID:
5155050
Journal Information:
Instrum. Exp. Tech. (Engl. Transl.); (United States), Journal Name: Instrum. Exp. Tech. (Engl. Transl.); (United States) Vol. 28:6, PT. 1; ISSN INETA
Country of Publication:
United States
Language:
English