Review of the Vogtle Units 1 and 2 Auxiliary Feedwater System reliability analysis

Technical Report ·
OSTI ID:5119945
This report presents the results of the review of the Auxiliary Feedwater System reliability analysis for the Vogtle Electric Generating Plant (VEGP) Units 1 and 2. The objective of this report is to estimate the probability that the Auxiliary Feedwater System will fail to perform its mission for each of three different initiators: (1) loss of main feedwater with offsite power available, (2) loss of offsite power, (3) loss of all ac power except vital instrumentation and control 125-V dc/120-V ac power. The scope, methodology, and failure data are prescribed by NUREG-0611, Appendix III. The results are compared with those obtained in NUREG-0611 for other Westinghouse plants.
Research Organization:
Brookhaven National Lab., Upton, NY (USA)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
5119945
Report Number(s):
NUREG/CR-4228; BNL-NUREG-51876; ON: TI86002329
Country of Publication:
United States
Language:
English