Field testing of the T-180/210-130 district heating turbine at Vilnius Power Plant 3, Lithuania. Final report
Technical Report
·
OSTI ID:50935
The purpose of this project was to demonstrate the unique technical features and performance of an advanced Russian 180-MW district heating turbine. The major task was to test the 180-MW district heating turbine at Vilnius Power Plant 3, Lithuania, with reference to the rotating grid-type diaphragms installed in the low pressure turbine sections to permit efficient extraction of steam for district heating. The field tests demonstrated that the turbine can be operated with a minimum cooling steam leakage rate through the grid-type diaphragms of about 1.5% of the nominal main steam flow rate.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (United States); Joseph Technology Corp., Inc., Woodcliff Lake, NJ (United States)
- Sponsoring Organization:
- Electric Power Research Inst., Palo Alto, CA (United States)
- OSTI ID:
- 50935
- Report Number(s):
- EPRI-TR--104958
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cold-related mortality vs heat-related mortality in a changing climate: A case study in Vilnius (Lithuania)
Steam turbines for district heating in nuclear power plants
Employment of steam turbine-gas turbine plants and gas turbine plants to increase the efficiency of district heating
Journal Article
·
Mon Oct 15 00:00:00 EDT 2018
· Environmental Research
·
OSTI ID:23105856
Steam turbines for district heating in nuclear power plants
Journal Article
·
Fri Mar 31 23:00:00 EST 1978
· Nucl. Technol.; (United States)
·
OSTI ID:5026105
Employment of steam turbine-gas turbine plants and gas turbine plants to increase the efficiency of district heating
Journal Article
·
Sun Dec 31 23:00:00 EST 1978
· Therm. Eng. (USSR) (Engl. Transl.); (United States)
·
OSTI ID:5249263