Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Endovascular occlusion of intracranial aneurysms with electrically detachable coils: Correlation of aneurysm neck size and treatment results

Journal Article · · AJNR. American Journal of Neuroradiology
OSTI ID:50588
; ; ;  [1]
  1. Univ. of California, Los Angeles, CA (United States)
To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average reported caliber of the major intracranial vessels was applied to determine the aneurysm neck sizes on the diagnostic angiograms. The cases were divided into two groups according to neck size, 4 mm being the discriminative value for small and wide necks. The posttreatment angiogram of each case was analyzed to evaluate the degree of occlusion achieved by the technique. Necks were successfully measured in 95% of the aneurysms. Complete aneurysm thrombosis was observed in 85% of the small-necked aneurysms and in 15% of the wide-necked aneurysms. Accurate angiographic measurements of neck diameter can be obtained in most aneurysms. The size of an aneurysm neck correlates well with the results of the endovascular treatment. Small-necked aneurysms can be satisfactorily occluded with this technique. In wide-necked aneurysms this technique should be reserved for lesions having a high surgical risk. 10 refs., 1 fig., 1 tab.
OSTI ID:
50588
Journal Information:
AJNR. American Journal of Neuroradiology, Journal Name: AJNR. American Journal of Neuroradiology Journal Issue: 5 Vol. 15; ISSN 0195-6108; ISSN AAJNDL
Country of Publication:
United States
Language:
English

Similar Records

Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug
Journal Article · Thu Feb 14 23:00:00 EST 2013 · Cardiovascular and Interventional Radiology · OSTI ID:22156499

Use of a Hydrogel-Coated Self-Expandable Coil to Salvage a Failed Transcatheter Embolization of a Mesenteric Hemorrhage
Journal Article · Thu Dec 14 23:00:00 EST 2006 · Cardiovascular and Interventional Radiology · OSTI ID:21091105

Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique
Journal Article · Wed Dec 14 23:00:00 EST 2011 · Cardiovascular and Interventional Radiology · OSTI ID:21608661