Use of a Hydrogel-Coated Self-Expandable Coil to Salvage a Failed Transcatheter Embolization of a Mesenteric Hemorrhage
Journal Article
·
· Cardiovascular and Interventional Radiology
HydroCoil (MicroVention, Aliso Viejo, CA, USA) is a self-expanding detachable coil developed to improve the endovascular occlusion of intracranial aneurysms. The hydrogel polymer covering the microcoil expands to several times its original diameter to enhance thrombosis of the intended vessel. We made use of this new technology to occlude a mesenteric artery pseudoaneurysm that failed superselective embolization with standard microcoils.
- OSTI ID:
- 21091105
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 6 Vol. 29; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
Microballoon Occlusion Test to Predict Colonic Ischemia After Transcatheter Embolization of a Ruptured Aneurysm of the Middle Colic Artery
Percutaneous Injection Therapy for a Peripheral Pulmonary Artery Pseudoaneurysm After Failed Transcatheter Coil Embolization
Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent
Journal Article
·
Tue Jul 15 00:00:00 EDT 2008
· Cardiovascular and Interventional Radiology
·
OSTI ID:21450358
Percutaneous Injection Therapy for a Peripheral Pulmonary Artery Pseudoaneurysm After Failed Transcatheter Coil Embolization
Journal Article
·
Mon Sep 15 00:00:00 EDT 2008
· Cardiovascular and Interventional Radiology
·
OSTI ID:21450343
Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent
Journal Article
·
Mon Feb 14 23:00:00 EST 2011
· Cardiovascular and Interventional Radiology
·
OSTI ID:21608740