This paper reports on a study of activity quantitation with pre-reconstruction Metz filtering and use of arithmetic mean pre-reconstruction, Chang's post-reconstruction, or Bellini's intrinsic attenuation correction that was conducted. Tc-99m filled spheres of various diameters were used to study activity estimation within an elliptical cross-section phantom. The percent of air sensitivity, which is calculated as the count rate for an ROI per unit activity for a source in the phantom divided by the count rate per unit activity for a point source in air times 100 percent, was used to assess the accuracy of attenuation correction. It was determined that a transmission model which explicitly included the buildup of scattered radiation yielded more accurate quantitation of activity in a uniform tub than correcting for scatter by scaling the counts with an average scatter fraction. The use of 2D pre-reconstruction Metz filtering combined with Bellini's intrinsic or Chang's post-reconstruction attenuation correction resulted in percent sensitivities which were the least position dependent and closest to 100 percent.
OSTI ID:
5012863
Journal Information:
IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States), Journal Name: IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) Vol. 38:2; ISSN 0018-9499; ISSN IETNA
Country of Publication:
United States
Language:
English

Similar Records

Compensation for nonuniform attenuation in SPECT brain imaging
Journal Article · Sun Mar 31 23:00:00 EST 1996 · IEEE Transactions on Nuclear Science · OSTI ID:248095

Implementation of simultaneous attenuation and detector response correction in SPECT
Conference · Sun Jan 31 23:00:00 EST 1988 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:7247429

Quantitative SPECT brain imaging: Effects of attenuation and detector response
Journal Article · Tue Jun 01 00:00:00 EDT 1993 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6309063