Orbit compensation for the time-varying elliptically polarized wiggler with switching frequency at 100 hz

Conference ·
OSTI ID:495798
In October 1996, the elliptically polarized wiggler, installed in the X13 straight section of the NSLS X-ray ring, was commissioned at an operating frequency of 100 hz. This wiggler generates circularly polarized photons in the energy range of 0.1 to 10 keV with AC modulation of polarization helicity. The vertical magnetic field is produced by a hybrid permanent magnet structure, and the horizontal magnetic field is generated by an electromagnet capable of switching at frequencies up to 100 hz. Here, the authors discuss the compensation of the residual vertical and horizontal orbit motion utilizing a time-domain algorithm employing a function generator to drive trim coils at the wiggler ends, and the wideband high precision orbit measurement system of the X-ray ring. The residual orbit motion has been reduced to a level below 1 micron, and the device has been run in regular operations with no negative effect on other users.
Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
495798
Report Number(s):
BNL--64471; CONF-970503--73; ON: DE97006721
Country of Publication:
United States
Language:
English

Similar Records

Orbit compensation for the time varying elliptically polarized wiggler
Journal Article · Sun Sep 01 00:00:00 EDT 1996 · Review of Scientific Instruments · OSTI ID:389527

The elliptical multipole wiggler project
Conference · Thu Jun 01 00:00:00 EDT 1995 · OSTI ID:80373

Characterization of a novel elliptically polarized wiggler