Measurements of water content of steam and drainage within the wet steam regime of the turbine. Research report No. 16 (in German)
Technical Report
·
OSTI ID:4937156
Measurements of drainage and water content of steam are presented in order to gain some information on the expansion conditions within the main turbine of the N.S. Otto Hahn.'' Due to the low superheating, expansion occurs already after the first two to three stages in the wet steam regime, and as the content of water increasing during expansion reduces the efficiency of the turbine, the water has to be removed through appropriate drainage devices in order to prevent erosion damage to the turbine blading due to drop formation. The measured data are used to determine whether and to what extent the constructional design of the turbine meets the requirements of wet steam separation. (GE)
- Research Organization:
- Gesellschaft fuer Kernenergieverwertung in Schiffbau und Schiffahrt m.b.H., Geesthacht-Tesperhude (F.R. Germany)
- Sponsoring Organization:
- Sponsor not identified
- NSA Number:
- NSA-29-017656
- OSTI ID:
- 4937156
- Report Number(s):
- GKSS--73-E-16
- Country of Publication:
- Germany
- Language:
- German
Similar Records
Combined gas turbine and steam turbine power station
LAYOUT AND CONSTRUCTION OF SATURATED STEAM TURBINES
Wet-steam erosion of steam turbine disks and shafts
Patent
·
Mon Jan 09 23:00:00 EST 1984
·
OSTI ID:6515973
LAYOUT AND CONSTRUCTION OF SATURATED STEAM TURBINES
Journal Article
·
Sun Nov 30 23:00:00 EST 1958
· Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys.
·
OSTI ID:4294513
Wet-steam erosion of steam turbine disks and shafts
Journal Article
·
Fri Jan 14 23:00:00 EST 2011
· Power Technology and Engineering (Print)
·
OSTI ID:22063953