PROTOTYPE RECIRCULATION PUMP TESTS. PATHFINDER ATOMIC POWER PLANT SUMMARY REPORT

Technical Report ·
OSTI ID:4843844

Results of tests performed on the Pathfinder Atomic Power Plant recirculation prototype pump and its components are presented. Tests included a preliminary seal test, a serrated bushing test, a cold performance test, and a hot loop test. Results indicated thut the pump should give trouble-free service in the field if operated as intended and within the limits specified. An analysis was made of the prototype trunnion supports for the Pathfinder recirculation pump. (M.C.G.)