FABRICATION AND INSPECTION PROCEDURES FOR EXPERIMENTAL GAS-COOLED REACTOR BURST-SLUG-DETECTION TUBE AND THERMOCOUPLE PENETRATIONS
Technical Report
·
OSTI ID:4843231
Satisfactory methods were developed for penetrating the stainless steel burst-slag-detection tubes and stainless steel-clad thermocouples through the carbon steel pressure shell of the Experimental Gas-Cooled Reactor (EGCR). The burst-slug-detection system permits the positive identification of a channel containing a defective fuel element. while the thermocouples will be used to measure temperatures from numerous points within the reactor. Both types of penetrations require the welding of relatively thin-walled compenents to thicker members under conditions of very limited accessibility. Suitable joint designs were determined and adequate fabrication and inspection procedures established in the construction of prototype demonstration assemblies. Conventional welding and brazing equipment and joining procedures were used throughout. Although accessibility in this application is definitely limited, it appears that welds and brazes of high quality can be made if carefully trained operators are utilized. (auth)
- Research Organization:
- Oak Ridge National Lab., Tenn.
- NSA Number:
- NSA-15-028803
- OSTI ID:
- 4843231
- Report Number(s):
- CF-61-8-29
- Country of Publication:
- United States
- Language:
- English
Similar Records
Zircaloy-Sheathed Fuel Element Rods Fitted with Thermocouples; BARRE COMBUSTIBLE A THERMOCOUPLE, GAINEE DE ZIRCALOY
BURST SLUG DETECTION EQUIPMENT SHIELDING--ANALYSIS
FUNCTIONAL TEST--BURST SLUG DETECTION SYSTEM
Technical Report
·
Mon Dec 31 23:00:00 EST 1962
·
OSTI ID:4158272
BURST SLUG DETECTION EQUIPMENT SHIELDING--ANALYSIS
Technical Report
·
Tue Nov 15 23:00:00 EST 1960
·
OSTI ID:4748587
FUNCTIONAL TEST--BURST SLUG DETECTION SYSTEM
Technical Report
·
Thu Feb 22 23:00:00 EST 1962
·
OSTI ID:4719798