CALIBRATION OF FUEL ELEMENT THERMOCOUPLES
Technical Report
·
OSTI ID:4830511
Tests in the thermocouple rig showed that fuel plate thermocouples of the type that will be used on the HTRE H-2 core will have an error of approximately 76 deg F if the a-c welder is used, 58 deg F if the d-c welder is used, and 82 deg F if the a-c welder is used with the wires not flattened. (auth)
- Research Organization:
- General Electric Co. Aircraft Nuclear Propulsion Dept., Cincinnati
- DOE Contract Number:
- AT(11-1)-171
- NSA Number:
- NSA-16-019068
- OSTI ID:
- 4830511
- Report Number(s):
- DC-55-6-12
- Country of Publication:
- United States
- Language:
- English