REACTOR PLANT CONTAINER INTEGRITY TEST. Section 3. Test Evaluation DLCS- 3570302
Technical Report
·
OSTI ID:4829465
Tests were conducted to inspect the interconnections and all pipe penetrations of the reactor plant container for signs of damage or rupture. A positive bolt tightness for the container hatches, reactor dome, and electrical stop joints was established by a bolt torquing sequence of tightening diametrically opposite bolts simultaneously. The conditions of all interconnections and pipe penetrations were satisfactory. (M.C.G.)