By use of the multisphere neutron spectrometer, the neutrons emitted from a sample of PuF4 were analyzed for average neutron energy. The results indicated an average neutron energy of 1.25 plus or minus 0.25 Mev. The room background had a fast neutron energy of 1.00 plus or minus 0.25 Mev, with a reasonably large contribution from scattered neutrons. A 110 gram sample of PuF/ sub 4/ gave a dose rate reading of about 9 mrem/hr at a distance of 30 cm, which corresponds to a neutron yield of 8.0 x 10/sup 5/ n/sec. The room background was about 0.5 mrem/hr. Neutrons originating in the PuF/sub 4/ processing equipment were measured with the 10 inch sphere neutron survey instrument. Comparable readings were obtained with the converted PeeWee neutron survey instrument by using a correction factor of 30, or a fast neutron energy of 0.5 or 0.4 Mev. Either of these factors enabled a monitor to obtain a more accurate dose rate with the PeeWee than was previously possible. (auth)
Research Organization:
Los Alamos Scientific Lab., N.Mex.
DOE Contract Number:
W-7405-ENG-36
NSA Number:
NSA-16-022967
OSTI ID:
4823452
Report Number(s):
LAMS-2692
Country of Publication:
United States
Language:
English

Similar Records

NEUTRON MEASUREMENTS AT HANFORD’S PLUTONIUM FINISHING PLANT
Technical Report · Mon Aug 10 00:00:00 EDT 2009 · OSTI ID:969172

Measurement of routinely encountered neutron doses in research facilities
Journal Article · Sat Oct 01 00:00:00 EDT 1983 · Radiation Protection Management; (United States) · OSTI ID:5228102

NEW METHODS OF NEUTRON DOSE RATE EVALUATION
Technical Report · Sun Dec 31 23:00:00 EST 1961 · OSTI ID:4764617