NEUTRON MEASUREMENTS AT HANFORD’S PLUTONIUM FINISHING PLANT
The Pacific Northwest National Laboratory (PNNL) conducted neutron measurements at Hanford’s Plutonium Finishing Plant (PFP). The measurements were performed to evaluate the performance of the Hanford Standard Dosimeter (HSD) and the 8816 TLD component of the Hanford Combination Neutron Dosimeter (HCND) in the neutron fields responsible for worker neutron exposures. For this study, TEPC detectors and multisphere spectrometers were used to measure neutron dose equivalent rate, and multispheres were used to measure average neutron energy. Water-filled phantoms holding Hanford dosimeters were positioned at each measurement location. The phantoms were positioned in the same location where a multisphere measurement was taken and TEPCs were also positioned there. Plant survey meters were also used to measure neutron dose rates at all locations. Three measurement locations were chose near the HC-9B glovebox in room 228A of Building 234-5. The multisphere spectrometers measured average neutron energies in the range of 337 to 555 keV at these locations. Personal dose equivalent, Hp(10)n, as measured by the multisphere and TEPC, ranged from 2.7 to 9.7 mrem/h in the three locations. Effective dose assuming a rotational geometry (EROT) was substantially lower than Hp(10), ranging from 1.3 to 3.6 mrem/h. These values were lower than the reported values from dosimeters exposed on a rotating phantom. Effective dose assuming an AP geometry (EAP) was also substantially lower than Hp(10), ranging from 2.3 to 6.5 mrem/h. These values were lower than the reported values from the dosimeters on slab phantoms. Since the effective dose values were lower than reported values from dosimeters, the dosimeters were shown to be conservative estimates of the protection quantities.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 969172
- Report Number(s):
- PNNL-18649
- Country of Publication:
- United States
- Language:
- English
Similar Records
VALIDATION OF HANFORD PERSONNEL AND EXTREMITY DOSIMETERS IN PLUTONIUM ENVIRONMENTS
Site-specific calibration of the Hanford personnel neutron dosimeter
Neutron dosimetry at commercial nuclear plants. Final report of Subtask C: /sup 3/He neutron spectrometer
Technical Report
·
Wed Feb 09 23:00:00 EST 2000
·
OSTI ID:968960
Site-specific calibration of the Hanford personnel neutron dosimeter
Conference
·
Sat Oct 01 00:00:00 EDT 1994
·
OSTI ID:10107319
Neutron dosimetry at commercial nuclear plants. Final report of Subtask C: /sup 3/He neutron spectrometer
Technical Report
·
Sat Sep 01 00:00:00 EDT 1984
·
OSTI ID:6517869