LATENT IMAGE FADING IN DOSIMETER FILM EMULSIONS
Technical Report
·
OSTI ID:4803936
Latent image fading in film emulsions produced by Foton for dosimeter purposes is investigated with regard to the influence of time. The decrease of density caused by latent image fading in normal conditions of storing and relative humidity of 50 to 80% does not exceed 10% during a year. This corresponds to the dose reading error up to 20%. (auth)
- Research Organization:
- Poland. Biuro Pelnomocnika Rzadu do Spraw Wykorzystania Energii Jadrowej. Centralne Laboratorium Ochrony Radiologicznej, Warsaw
- NSA Number:
- NSA-16-025645
- OSTI ID:
- 4803936
- Report Number(s):
- CLOR-11
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-62
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
LATENT-IMAGE FADING IN FILM BADGE DOSIMETERS
LATENT IMAGE FADING IN DUPONT TYPE 555 PERSONNEL MONITORING FILM AT CHALK RIVER
Effects of the Relative Humidity on Latent Image Fading and Sensitivity of the Film Emulsion
Journal Article
·
Sat Oct 01 00:00:00 EDT 1960
· Health Physics (England)
·
OSTI ID:4803936
LATENT IMAGE FADING IN DUPONT TYPE 555 PERSONNEL MONITORING FILM AT CHALK RIVER
Technical Report
·
Sun Sep 01 00:00:00 EDT 1963
·
OSTI ID:4803936
Effects of the Relative Humidity on Latent Image Fading and Sensitivity of the Film Emulsion
Journal Article
·
Wed Aug 01 00:00:00 EDT 1962
· Radioisotopes (Tokyo)
·
OSTI ID:4803936